improve power route handler and error handling,
add test sim for bmc power sw
This commit is contained in:
61
hw/BMC_PW_SW_Sim.asc
Normal file
61
hw/BMC_PW_SW_Sim.asc
Normal file
@@ -0,0 +1,61 @@
|
||||
Version 4
|
||||
SHEET 1 1792 680
|
||||
WIRE 240 -208 176 -208
|
||||
WIRE 448 -208 320 -208
|
||||
WIRE 1040 -208 448 -208
|
||||
WIRE 448 -64 448 -208
|
||||
WIRE 528 -64 496 -64
|
||||
WIRE 560 -64 528 -64
|
||||
WIRE 1040 -64 1040 -208
|
||||
WIRE 496 -48 496 -64
|
||||
WIRE 176 0 176 -208
|
||||
WIRE 496 16 496 0
|
||||
WIRE 560 16 496 16
|
||||
WIRE 1152 16 1088 16
|
||||
WIRE 1280 16 1232 16
|
||||
WIRE 1312 16 1280 16
|
||||
WIRE 176 144 176 80
|
||||
WIRE 448 144 448 16
|
||||
WIRE 448 144 176 144
|
||||
WIRE 1040 144 1040 32
|
||||
WIRE 1040 144 448 144
|
||||
WIRE 176 176 176 144
|
||||
WIRE 1312 176 1312 96
|
||||
FLAG 176 176 0
|
||||
FLAG 448 -208 PW_SW
|
||||
FLAG 528 -64 SIG_SW
|
||||
FLAG 1280 16 SIG_BMC
|
||||
FLAG 1312 176 0
|
||||
SYMBOL voltage 176 -16 R0
|
||||
WINDOW 123 0 0 Left 0
|
||||
WINDOW 39 0 0 Left 0
|
||||
SYMATTR InstName V1
|
||||
SYMATTR Value 5
|
||||
SYMBOL res 336 -224 R90
|
||||
WINDOW 0 0 56 VBottom 2
|
||||
WINDOW 3 32 56 VTop 2
|
||||
SYMATTR InstName R1
|
||||
SYMATTR Value 10k
|
||||
SYMBOL sw 448 32 R180
|
||||
SYMATTR InstName S1
|
||||
SYMATTR Value SW1
|
||||
SYMBOL voltage 560 -80 R0
|
||||
WINDOW 123 0 0 Left 0
|
||||
WINDOW 39 0 0 Left 0
|
||||
SYMATTR InstName V2
|
||||
SYMATTR Value PULSE(0 1 0.1 0 0 0.1 0.5 2)
|
||||
SYMBOL voltage 1312 0 R0
|
||||
WINDOW 123 0 0 Left 0
|
||||
WINDOW 39 0 0 Left 0
|
||||
SYMATTR InstName V4
|
||||
SYMATTR Value PULSE(0 3.3 0.3 0 0 0.1 0.3 2)
|
||||
SYMBOL nmos 1088 -64 M0
|
||||
SYMATTR InstName M1
|
||||
SYMATTR Value Si7336ADP
|
||||
SYMBOL res 1248 0 R90
|
||||
WINDOW 0 0 56 VBottom 2
|
||||
WINDOW 3 32 56 VTop 2
|
||||
SYMATTR InstName R2
|
||||
SYMATTR Value 1k
|
||||
TEXT 472 -120 Left 2 !.model SW1 sw(Vh=0 Vt=0.5)
|
||||
TEXT 176 -312 Left 2 !.tran 1
|
Reference in New Issue